Thiết bị đo lường ngành nước
Last update:
10/08/2021
ENVIDATA 1801 Inventia - Truyền dữ liệu quan trắc tự động
2846 Views •con::cube_V3_EN S::CAN Datasheet
1444 Views •ammo::lyser_eco_ww_EN S::CAN Datasheet
1377 Views •soli::lyser_ww_EN S::CAN Datasheet
1258 Views •condu::lyser_dw_EN S::CAN Datasheet
1253 Views •con::lyte_EN S::CAN Datasheet
1250 Views •Easychem Coli Online - Coliform & E coli analyser - Systea Datasheet
1233 Views •Open Channel Flow Meter 713 (MJK)
1232 Views •Alyza IQ_NH4 WTW Xylem Datasheet
1231 Views •spectro::lyser_V3_ww_EN S::CAN Datasheet
1198 Views •Turbidity and Suspended Solids (WTW)
1196 Views •MicC_uLFR HT FC - TN@220nm - Micromac Total Nitrogen - Systea Datasheet
1167 Views •con::nect_V3 S::CAN Datasheet
1165 Views •ammo::lyser_pro_ww_EN S::CAN Datasheet
1158 Views •Magflux Electromagnetic Flow Meter (MJK)
1158 Views •Dissolved Oxygen Measurement (WTW)
1155 Views •Conductivity Measurement (WTW)
1142 Views •i::scan_dw_EN S::CAN Datasheet
1133 Views •Optical TSS sensor (WTW)
1131 Views •Alyza IQ PO4 WTW Xylem Datasheet
1124 Views •Digital ISE sensor AmmoLyt® for ammonium
Ammonium measurement directly in the medium without sample preparation and sample transfer. Measurement of centrate and other process waters up to 2,000 mg/l NH4-N
Measuring method: Electrochemical
Appropriate Electrode: Reference electrode VARiON® Ref, Measuring electrode VARiON®Plus NO3, Compensation electrode VARiON®Plus Cl
Measuring range/Resolution
NH4-N: 1 ... 2,000 mg/l / 1 mg/l; 0.1 ... 100 mg/l / 0.1 mg/l
NH4+: 1 ... 2,580 mg/l / 1 mg/l; 0.1 ... 129.0 mg/l / 0.1 mg/l
Compensation Range: K+: 0.1 ... 1,000 mg/l / 0.1 mg/l
Measuring Accuracy in laboratory standard solutions
± 5 % of measured value ± 0.2 mg/l in standard solutions
Ammonium measurement directly in the medium without sample preparation and sample transfer. Measurement of centrate and other process waters up to 2,000 mg/l NH4-N
Measuring method: Electrochemical
Appropriate Electrode: Reference electrode VARiON® Ref, Measuring electrode VARiON®Plus NO3, Compensation electrode VARiON®Plus Cl
Measuring range/Resolution
NH4-N: 1 ... 2,000 mg/l / 1 mg/l; 0.1 ... 100 mg/l / 0.1 mg/l
NH4+: 1 ... 2,580 mg/l / 1 mg/l; 0.1 ... 129.0 mg/l / 0.1 mg/l
Compensation Range: K+: 0.1 ... 1,000 mg/l / 0.1 mg/l
Measuring Accuracy in laboratory standard solutions
± 5 % of measured value ± 0.2 mg/l in standard solutions