Thiết bị đo lường ngành nước
Last update:
09/08/2021
MicC_uLFR HT - TMn - Micromac Manganese Total - Systea Datasheet
2969 Views •MicC_Chromium6+ - Micromac Chromium 6+ - Systea Datasheet
2466 Views •MicC_uLFR HT DR - TFe - Micromac Total Iron - Systea Datasheet
2319 Views •MicCfa_Cyanide Total - Micromac Cyanide Total - Systea Datasheet
2446 Views •ENVIDATA 1801 Inventia - Truyền dữ liệu quan trắc tự động
7648 Views •MicC_uLFR HT FC - TN@220nm - Micromac Total Nitrogen - Systea Datasheet
3456 Views •Open Channel Flow Meter 713 (MJK)
3378 Views •con::cube_V3_EN S::CAN Datasheet
3328 Views •Easychem Coli Online - Coliform & E coli analyser - Systea Datasheet
3105 Views •ammo::lyser_eco_ww_EN S::CAN Datasheet
3051 Views •con::lyte_EN S::CAN Datasheet
3043 Views •MicC_uLFR HT - TMn - Micromac Manganese Total - Systea Datasheet
2969 Views •MicC_Phosphate - Micromac Phosphate - Systea Datasheet
2869 Views •Alyza IQ_NH4 WTW Xylem Datasheet
2764 Views •Alyza IQ PO4 WTW Xylem Datasheet
2728 Views •Optical TSS sensor (WTW)
2709 Views •MicC_uLFR HT DR - TP - Micromac Total Phosphorus - Systea Datasheet
2704 Views •i::scan_dw_EN S::CAN Datasheet
2702 Views •soli::lyser_ww_EN S::CAN Datasheet
2685 Views •carbo::lyser_V3_ww_EN S::CAN Datasheet
2640 Views •spectro::lyser_V3_ww_EN S::CAN Datasheet
2636 Views •ammo::lyser_pro_ww_EN S::CAN Datasheet
2635 Views •condu::lyser_dw_EN S::CAN Datasheet
2633 Views •Turbidity and Suspended Solids (WTW)
2623 Views •MICROMAC TOTAL MANGANESE is a microprocessor controlled On Line analyzer specifically designed for automatic Total Manganese monitoring on several types of water matrix.
ROBUST AND RELIABLE
Designed for industrial and Environmental On Line applications Micromac C ensures the highest level of robustness in the electronics, mechanics and hydraulics components. Complete separation between electronics and hydraulics plus a simple and robust LFA* hydraulics allows easy maintenance and long terms reliable operations.
* LFA: Loop Flow Analysis patent pending
Technical Specifications
MEASURING PRINCIPLE: Colorimetric, Formaldoxine method, combined UV + HT digestion
COLORIMETER: dual beam, silicon detector
MEASUREMENT TYPE: cyclic; MEASURING INTERVAL: programmable
MEASURING TIME: 13-15 minutes depending on the ragem
MEASURING RANGE: 0-2 ppm Mn, other ranges available on request
DETECTION LIMIT: typically better 3% of the full scale, calculated as for EPA p. 136 appendix B
REPEATABILITY: better than 5%; SD% of 7 replicates at 50% of the full scale
ACCURACY: better than 5% 7 replicates at 20% of the full scale
OUTPUT SIGNAL: 4-20 mA INPUT SIGNALS: n. 1 Analysis, n. 1 calibration; digital contacts
ALARMS: n. 1 High Limit, n. 1 General, n. 1 Calibration; potential free contacts
SAMPLE AND WASTE DELIVERY: pressure free; SAMPLE TEMPERATURE: 10 °C- 30 °C
REAGENTS REPLACEMENT: 3/4 weeks depending on the operating temperature
PROTECTION: IP55
HARDWARE: PC104 industrial standard, Integrated keyboard and graphics display, RS232 option
POWER SUPPLY: 12 V DC external power supply included; 4W Standby; 50 W (mean) analysis
WEIGHT: 33 Kg without reagents; DIMENSION: 800x420x280 mm(hxwxd)
ROBUST AND RELIABLE
Designed for industrial and Environmental On Line applications Micromac C ensures the highest level of robustness in the electronics, mechanics and hydraulics components. Complete separation between electronics and hydraulics plus a simple and robust LFA* hydraulics allows easy maintenance and long terms reliable operations.
* LFA: Loop Flow Analysis patent pending
Technical Specifications
MEASURING PRINCIPLE: Colorimetric, Formaldoxine method, combined UV + HT digestion
COLORIMETER: dual beam, silicon detector
MEASUREMENT TYPE: cyclic; MEASURING INTERVAL: programmable
MEASURING TIME: 13-15 minutes depending on the ragem
MEASURING RANGE: 0-2 ppm Mn, other ranges available on request
DETECTION LIMIT: typically better 3% of the full scale, calculated as for EPA p. 136 appendix B
REPEATABILITY: better than 5%; SD% of 7 replicates at 50% of the full scale
ACCURACY: better than 5% 7 replicates at 20% of the full scale
OUTPUT SIGNAL: 4-20 mA INPUT SIGNALS: n. 1 Analysis, n. 1 calibration; digital contacts
ALARMS: n. 1 High Limit, n. 1 General, n. 1 Calibration; potential free contacts
SAMPLE AND WASTE DELIVERY: pressure free; SAMPLE TEMPERATURE: 10 °C- 30 °C
REAGENTS REPLACEMENT: 3/4 weeks depending on the operating temperature
PROTECTION: IP55
HARDWARE: PC104 industrial standard, Integrated keyboard and graphics display, RS232 option
POWER SUPPLY: 12 V DC external power supply included; 4W Standby; 50 W (mean) analysis
WEIGHT: 33 Kg without reagents; DIMENSION: 800x420x280 mm(hxwxd)
Views | |
---|---|
2969 | Total Views |
1 | Members Views |
2968 | Public Views |
Chia sẻ qua email
Vui lòng đăng nhập to share this document by email.
Đã nhúng trong trang web của bạn
Chọn trang để bắt đầu với