Thiết bị đo lường ngành nước
Last update:
10/08/2021
Easychem Coli Online - Coliform & E coli analyser - Systea Datasheet
6156 Views •SAC and Nitrate measurement (WTW)
4506 Views •i::scan_ww_EN S::CAN Datasheet
4740 Views •multi::lyser_V3_ww_EN S::CAN Datasheet
4316 Views •spectro::lyser_V3_ww_EN S::CAN Datasheet
5777 Views •carbo::lyser_V3_ww_EN S::CAN Datasheet
5497 Views •ammo::lyser_eco_ww_EN S::CAN Datasheet
6090 Views •ENVIDATA 1801 Inventia - Truyền dữ liệu quan trắc tự động
13398 Views •MicC_uLFR HT FC - TN@220nm - Micromac Total Nitrogen - Systea Datasheet
7031 Views •con::cube_V3_EN S::CAN Datasheet
6612 Views •Open Channel Flow Meter 713 (MJK)
6482 Views •MicC_uLFR HT - TMn - Micromac Manganese Total - Systea Datasheet
6216 Views •Easychem Coli Online - Coliform & E coli analyser - Systea Datasheet
6156 Views •con::lyte_EN S::CAN Datasheet
6106 Views •ammo::lyser_eco_ww_EN S::CAN Datasheet
6090 Views •MicC_Phosphate - Micromac Phosphate - Systea Datasheet
5945 Views •Alyza IQ_NH4 WTW Xylem Datasheet
5842 Views •spectro::lyser_V3_ww_EN S::CAN Datasheet
5777 Views •Alyza IQ PO4 WTW Xylem Datasheet
5741 Views •condu::lyser_dw_EN S::CAN Datasheet
5728 Views •MicC_uLFR HT DR - TP - Micromac Total Phosphorus - Systea Datasheet
5718 Views •Optical TSS sensor (WTW)
5689 Views •ammo::lyser_pro_ww_EN S::CAN Datasheet
5651 Views •Turbidity and Suspended Solids (WTW)
5646 Views •i::scan_dw_EN S::CAN Datasheet
5611 Views •soli::lyser_ww_EN S::CAN Datasheet
5554 Views •MicCfa_Cyanide Total - Micromac Cyanide Total - Systea Datasheet
5541 Views •EASYCHEM COLI ONLINE
MEASURING PRINCIPLE: Colorimetric (Total & Faecal Coliforms) and fluorimetric (E. coli)
MEASUREMENT TYPE: Fully automated, direct read, on-line discrete analyser for Presence/Absence (P/A) and Most Probable Number (MPN)
MEASUREMENT SENSITIVITY:
1 CFU / 100 mL (P/A)
1.8 – 1,250 up to 17,500 MPN /100 mL (MTF)
Other measurement ranges are programmable, according to the expected concentrations and the analytical frequency
MPN MEASUREMENT
FREQUENCY Up to 12 samples / day (Range depending on customer set-up)
MPN MEASUREMENT
TIME: 15-18 hours
MEASURING POINTS: One, multipoint as option
OPERATOR INTERFACE: Colour graphic touch-screen 15” display
MEASURING PRINCIPLE: Colorimetric (Total & Faecal Coliforms) and fluorimetric (E. coli)
MEASUREMENT TYPE: Fully automated, direct read, on-line discrete analyser for Presence/Absence (P/A) and Most Probable Number (MPN)
MEASUREMENT SENSITIVITY:
1 CFU / 100 mL (P/A)
1.8 – 1,250 up to 17,500 MPN /100 mL (MTF)
Other measurement ranges are programmable, according to the expected concentrations and the analytical frequency
MPN MEASUREMENT
FREQUENCY Up to 12 samples / day (Range depending on customer set-up)
MPN MEASUREMENT
TIME: 15-18 hours
MEASURING POINTS: One, multipoint as option
OPERATOR INTERFACE: Colour graphic touch-screen 15” display