CEMS - Hệ thống quan trắc khí thải tự động
Last update:
13/08/2021
GCEM 40 Datasheet Gas Monitoring - CODEL - CEMS Document
3020 Views •S700 Gas Analyzer-SICK catalogue-TAILOR-MADE-CEMS-Gas analysis
3044 Views •ABB CEMS Datasheet-ABB CEMS solution and products information
2963 Views •GCEM 4000 Datasheet Gas Monitoring - CODEL - CEMS Document
2233 Views •GCEM 4100 Datasheet Gas Monitoring - CODEL - CEMS Document
2178 Views •EasyLine EL3000 Series-ABB CEMS Datasheet-Continuous Gas Analyzers
2204 Views •ACX Gas Analyzer System-ABB CEMS Datashete
3633 Views •GCEM 40E Datasheet Gas Monitoring - CODEL - CEMS Document
2998 Views •PowerCEMS100-SICK catalogue-CEMS-EFFICIENT SYSTEM-Gas analysis for Power Plants
2799 Views •ACX Gas Analyzer System-ABB CEMS Datashete
3633 Views •SmartCem Datasheet 2 - CODEL - CEMS Document
3533 Views •SmartCem Datasheet - CODEL - CEMS Document
3332 Views •DCEM2000_2100 Datasheet Dust Monitoring - CODEL - CEMS Document
3205 Views •EnergyTech 301 Datasheet Dust Monitor - CEMS CODEL
3170 Views •S700 Gas Analyzer-SICK catalogue-TAILOR-MADE-CEMS-Gas analysis
3044 Views •GCEM 40 Datasheet Gas Monitoring - CODEL - CEMS Document
3020 Views •GCEM 40E Datasheet Gas Monitoring - CODEL - CEMS Document
2998 Views •ABB CEMS Datasheet-ABB CEMS solution and products information
2963 Views •DCEM1000_1001 Dust Monitoring - CODEL - CEMS Document
2839 Views •PowerCEMS100-SICK catalogue-CEMS-EFFICIENT SYSTEM-Gas analysis for Power Plants
2799 Views •DustHunter T50-SICK catalogue-Transmittance dust measuring devices
2787 Views •FLOWSIC100-SICK catalogue-Volume Flow Measuring Device
2743 Views •VCEM5000_5100 Datasheet Flow Monitoring - CODEL - CEMS Document
2460 Views •GCEM 4000 Datasheet Gas Monitoring - CODEL - CEMS Document
2233 Views •EasyLine EL3000 Series-ABB CEMS Datasheet-Continuous Gas Analyzers
2204 Views •GCEM 4100 Datasheet Gas Monitoring - CODEL - CEMS Document
2178 Views •Model G-CEM4100 Extractive Flue Gas Analyser
Extractive Flue Gas Analyser
The G-CEM4100 is a hot extractive analyser for difficult flue gas monitoring applications. It uses infrared absorption spectroscopy to measure up to seven pollutant species in a single self-contained unit.
Many conventional extractive systems require the sampled gas to be cleaned and dried to a very high standard prior to analysis, invariably resulting in a high maintenance demand. Such elaborate pre-conditioning is not required; the G-CEM4100 creates ‘perfect’ duct conditions in a temperature controlled chamber within a separate free-standing, air-conditioned cabinet. Process gases are simply cooled (or heated) then transferred along a heated sample line, without further conditioning, to be measured using a CODEL multi-channel analyser housed in the cabinet.
Increasingly, environmental agencies demand that continuous emission analysers have the facility to prove their performance using known concentration audit gases. The G-CEM4100 provides the facility to automatically check and control zero using clean, dry compressed air (or N2). Where independent span checks are required, bottled gases of known concentration can be injected directly into the measurement chamber.
- multi-species infrared absorption analyser for up to seven gas species
- extractive system to local analyser with full zero & span verification using audit gases
- real-time normalisation for STP & H2O ppm, mg/m3 (measured) & mg/Nm3 (normalised)
- automatic calibration verification facility and full range of outputs & alarms
- 5 years+ data logging via pc software package remote access for diagnostic checks via modem
- full EMC & LVD approvals
Extractive Flue Gas Analyser
The G-CEM4100 is a hot extractive analyser for difficult flue gas monitoring applications. It uses infrared absorption spectroscopy to measure up to seven pollutant species in a single self-contained unit.
Many conventional extractive systems require the sampled gas to be cleaned and dried to a very high standard prior to analysis, invariably resulting in a high maintenance demand. Such elaborate pre-conditioning is not required; the G-CEM4100 creates ‘perfect’ duct conditions in a temperature controlled chamber within a separate free-standing, air-conditioned cabinet. Process gases are simply cooled (or heated) then transferred along a heated sample line, without further conditioning, to be measured using a CODEL multi-channel analyser housed in the cabinet.
Increasingly, environmental agencies demand that continuous emission analysers have the facility to prove their performance using known concentration audit gases. The G-CEM4100 provides the facility to automatically check and control zero using clean, dry compressed air (or N2). Where independent span checks are required, bottled gases of known concentration can be injected directly into the measurement chamber.
- multi-species infrared absorption analyser for up to seven gas species
- extractive system to local analyser with full zero & span verification using audit gases
- real-time normalisation for STP & H2O ppm, mg/m3 (measured) & mg/Nm3 (normalised)
- automatic calibration verification facility and full range of outputs & alarms
- 5 years+ data logging via pc software package remote access for diagnostic checks via modem
- full EMC & LVD approvals